FEREX 4.035
The FEREX 4.035 Fluxgate magnetometer detects disruptions in the earth's magnetic field caused by ferromagnetic objects. It is suitable for a wide range of applications thanks to its great depth of detection compared with EMI detectors. The extremely sensitive MG-10-550 probe minimizes noise. This makes the FEREX ideal for detecting iron. Even searches beneath high-voltage power lines and along fences, pipelines, and railroad tracks are easy with the FEREX.
Product details
- Maximum sensitivity and minimum noise level bomb locator
- Built-in filters for searching under power lines
- Special mode for searching along fences, pipelines and railway tracks
- Special mode for the suppression of small objects
- Compact detector in one piece design
Technical specification
FEREX 4.035 |
|
Weight | 3.3 kg complete detector incl. batteries 11.1 kg complete detector set in case |
Dimensions | FEREX - 1,250 mm (H) Case - 989 x 415 x 157 mm (H x W x D) |
Temperatur ranges | Operation: -37 °C to +71 °C; -99 °F to +160 °F (ambient temperature) Storage: -57 °C to +71 °C; -135 °F to +160 °F |
Power supply | 4 x 1.5 V alkaline batteries (LR20) or 4 x 1.2 V NiMH (HR20) |
Battery lifetime | > 70 hours |
Battery size | IEC LR20/HR20 - ANSI „D“ |
Measuring ranges | 7 linear ranges: 0 - 10 nT to 0 - 10,000 nT |
Compensation range | ±950 nT |
Protection grade | IP 65 |
Probe MG-10-550 |
|
Type | Fluxgate gradiometer |
Base distance | 550 mm |
Application area | ±62,500 nT |
Measuring range | ±10,000 nT gradient ±62,500 nT absolute |
Reference point | 97.5 mm from end of probe rod, 4 mm outside symmetry axis |
Declination | ±3 nT |
Noise | <40 pTV Hz @ 1 Hz |
Cut-off frequency | 230 Hz |
Temperature drift | <1 nT/K |
Uncertainty of measurement | <2 % ref. ±10,000 nT |
Linearity | <1 nT referred to maximum measuring range |
Protection grade | IP 68, 100 m with optional sealing plug |
External dimensions | Diameter 39.4 mm (with protective cap), probe length 750 mm, base distance 550 mm |
Certifications |
|
MIL-Standards certifications | MIL-STD 810G Method 514.6, Procedure I, Random Vibration MIL-STD 810G Method 516.6, Procedure I, Mechanical Shock MIL-STD 810G Method 516.6, Procedure IV, Transit Drop Test MIL-STD 810G Method 501.5, Procedure I, High Temperature MIL-STD 810G Method 502.5, Procedure I, Low Temperature MIL-STD 810G Method 503.5, Procedure I-C, Temperatur Shock MIL-STD 810G Method 506.5, Procedure I, Blowing Rain MIL-STD 461G RE102 Radiated Emission MIL-STD 461G RS103 Radiated Susceptibility AEODP-7 Edition B, Annex A-1 European Directive 2014/30/EC, EN 61326-1 |
NATO Stock Nummer (NSN) | 6665-12-420-7755 |