The Mi-TIC E thermal imaging camera provides a crystal clear image with a dynamic range up to 1400°F (760°C) and at the same time can still see very low temperature objects, which is ideal for casualty searches.

Applications include ventilation location selection; search and rescue (fire and non-fire); seat of fire localization; overhaul; size-up.

Product details

Ease of Use

  • Available in 1- or 3-button options

  • 3-button models are user configurable

  • On/Off / NFPA "TI BASIC" button

  • Lightest NFPA 1801 compliant thermal imager at just 1.7lb (755g)

Image Quality

  • 320x240 Resolution; Display size diagonal - 2.7" (69mm)

  • High dynamic temperature range up to 1400°F (760°C)

  • Uninterrupted imaging with Tri-Mode Sensitivity

  • Unmistakeable fixed scene colorization

  • Digital spot temperature measurement (3-button models only)

  • Dynamic Scene Enhancement

Powered by the Ignis Engine

  • Enhanced image quality

  • Latest sensor technology

  • Class leading battery technology with 5-year warranty

Designed to Meet Your Application

  • Image freeze, image capture and video capture (3-button models only)

  • Software customization tool- activate/deactivate desired functionality

  • Compact Truck Charger - space saving smart charger ensures camera is ready to respond

Technical specification

Environmental Data

Thermal conditions
The camera has been designed to operate:
Continuously between -20°C (-4°F) and +85°C (185°F)
At 150°C (300°F) for 15 minutes
At 260°C (500°F) for 7 minutes
Sealing
IP67; will withstand short-term immersion in water
Impact
The camera will withstand a drop from a height of 2m (6.5ft) onto concrete
Storage
It is recommended that, for maximum effective operational life, the storage temperature is kept between -20°C (-4°F) and +40°C (104°F)

Detector

Sensor type
Un-cooled Microbolometer
Sensor material
Amorphous Silicon (ASi)
Resolution
384 x 288px
Pixel size
17µm
Spectral response
7.5 – 14µm
MDTD (Full camera system sensitivity)
60mK (0.06°C) typical (Minimum Discernible Temperature Difference)
NETD (Sensor sensitivity)
<50mK (<0.05°C)
Dynamic range
-40°C to 760°C (-40°F to 1400°F)
Refresh rate
60Hz
Direct Temperature Measurement (DTM)
-40°C to 760°C (-40°F to 1400°F)

Lens

Lens material
Germanium Composite
Focal length
1m to infinity, optimized at 4m (3ft to infinity, optimized at 13ft)
Aperture
f/1.0
Field of View
50° horizontal, 37.5° vertical, 62° diagonal

Display

Type
High-grade, industrial, color TFT active matrix LCD
Size
69mm (2.7”)
Pixel format
QVGA 320 x 240 (each pixel RGB format; total 230,400 pixels)
Video input
Sensor synchronized direct digital drive
Backlight
400cd/m2

Mechanical Data

Camera dims (H x W x D)
203mm x 96mm x 71mm (8.0” x 3.7” x 2.8”)
Camera weight
580g (1.3lb) without battery
755g (1.7lb) with standard battery
Std Battery dims (H x W x D)
87mm x 76mm x 28mm (3.4” x 3.0” x 1.1”)
Std Battery weight
175g (6oz)
Charger dims (H x W x D)
167mm x 112mm x 120mm (6.5” x 4.4” x 4.7”)
Charger weight
600g (1.3lb)
Main camera body
Radel® R-5100 and Santoprene®
LCD window
Ultrason® E 2010 HC
LCD bumper
Santoprene®
Ge Window collar
Radel® R-5100 and Santoprene®
Lens window
Germanium (2mm thick) with durable coating

Electrical Data

Power consumption
<3 W typical
Start-up time
5 seconds typical
Std Battery type
Lithium Iron Phosphate Rechargeable Battery
Std Battery capacity
1800 mAh, 6.4V
Std Battery life
In excess of 4 hours @ ambient temperature (22°C / 72°F)
Std Battery charge time
Less than 4 hours
Std Battery recharge cycles
Over 2000 cycles
Std Battery sealing
IP67
Std Battery charging temp.
5°C to 40°C (41°F to 104°F)
Charger input voltage
11V – 30V DC (12V and 24V vehicle systems)
Charger operating temp.
0°C to 40°C (32°F to 104°F)

Compliance Data

Performance
NFPA 1801:2021 Standard on Thermal Imagers for the Fire Service
Safety
IEC 62368-1:2014 and related national standards
UL 121201 / CSA C22.2 No. 213:2017 Class I, Div 2,
Groups C, D T4; Class II, Div 2 Groups F, G T4
Emissions RFI/EMC
EN 55032:2015, Class A
EN 54098:2010
FCC CFR 47 subpart 15b, ICES 003:2017
AUS/NZ 4251.1
Immunity
EN 55103-2:2009
Vibration/Shock
BS EN 60721-3-2 Class 2M3
RoHS
All parts of the system are compliant with EU directive 2011/65/EC