The Mi-TIC 320 provides a crystal clear image with a superb dynamic range up to 2000°F (1100°C). You can clearly view extremely high temperatures without whiteout and at the same time still see very low temperature objects, which is ideal for casualty searches.

The camera also includes Heat Seeker (hottest spot identifier) and Cold Seeker (coldest spot identifier) technology.

Applications include: Ventilation location selection, Search and rescue (fire and non-fire), Seat of fire localization, Overhaul, Size-up, Interior structural firefighting, Hot spot localization, Cold spot localization.

Product details

Ease of Use

  • Available in 3-button option only

  • User configurable

  • On/Off / NFPA "TI BASIC" button

  • Lightest NFPA 1801 compliant thermal imager at just 1.7lb (755g)

Image Quality

  • 320x240 Resolution; Display size diagonal - 2.7" (69mm)

  • Highest dynamic temperature range up to 2000°F (1100°C)

  • Uninterrupted imaging with Tri-Mode Sensitivity

  • Unmistakable fixed scene colorization

  • Digital spot temperature measurement

  • Dynamic Scene Enhancement

Powered by the Ignis Engine

  • Enhanced image quality

  • Latest sensor technology

  • Class leading battery technology with 5-year warranty

Designed to Meet Your Application

  • Image freeze, image capture and video capture

  • Software customization tool - activate/deactivate desired functionality

  • Compact Truck Charger- space saving smart charger ensures the camera is ready to respond

Technical specification

Environmental Data

Thermal conditions The camera has been designed to operate:
Continuously between -20°C (-4°F) and +85°C (185°F)
At 150°C (300°F) for 15 minutes
At 260°C (500°F) for 7 minutes
Sealing IP67; will withstand short-term immersion in water
Impact The camera will withstand a drop from a height of 2m (6.5ft) onto concrete
Storage It is recommended that, for maximum effective operational life, the storage temperature is kept between -20°C (-4°F) and +40°C (104°F)

Detector

Sensor type Un-cooled Microbolometer
Sensor material Amorphous Silicon (ASi)
Resolution 384 x 288px
Pixel size 17µm
Spectral response 7.5 – 14µm
MDTD (Full camera system sensitivity) 60mK (0.06°C) typical (Minimum Discernible Temperature Difference)
NETD (Sensor sensitivity) <50mK (<0.05°C)
Dynamic range -40°C to 1100°C (-40°F to 2000°F)
Refresh rate 60Hz
Direct Temperature Measurement (DTM) -40°C to 1100°C (-40°F to 2000°F)

Lens

Lens material Germanium Composite
Focal length 1m to infinity, optimized at 4m (3ft to infinity, optimized at 13ft)
Aperture f/1.0
Field of view 50° horizontal, 37.5° vertical, 62° diagonal

Display

Type High-grade, industrial, color TFT active matrix LCD
Size 69mm (2.7”)
Pixel format QVGA 320 x 240 (each pixel RGB format; total 230,400 pixels)
Video input Sensor synchronized direct digital drive
Backlight 400cd/m2

Mechanical Data

Camera dims (H x W x D) 203mm x 96mm x 71mm (8.0” x 3.7” x 2.8”)
Camera weight 580g (1.3lb) without battery
755g (1.7lb) with standard battery
Std Battery dims (H x W x D) 87mm x 76mm x 28mm (3.4” x 3.0” x 1.1”)
Std Battery weight 175g (6oz)
Charger dims (H x W x D) 167mm x 112mm x 120mm (6.5” x 4.4” x 4.7”)
Charger weight 600g (1.3lb)
Main camera body Radel® R-5100 and Santoprene®
LCD window Ultrason® E 2010 HC
LCD bumper Santoprene®
Ge Window collar Radel® R-5100 and Santoprene®
Lens window Germanium (2mm thick) with durable coating

Electrical Data

Power consumption <3 W typical
Start-up time 5 seconds typical
Std Battery type Lithium Iron Phosphate Rechargeable Battery
Std Battery capacity 1800 mAh, 6.4V
Std Battery life In excess of 4 hours @ ambient temperature (22°C / 72°F)
Std Battery charge time Less than 4 hours
Std Battery recharge cycles Over 2000 cycles
Std Battery sealing IP67
Std Battery charging temp. 5°C to 40°C (41°F to 104°F)
Charger input voltage 11V – 30V DC (12V and 24V vehicle systems)
Charger operating temp. 0°C to 40°C (32°F to 104°F)

Compliance Data

Performance NFPA 1801:2021 Standard on Thermal Imagers for the Fire Service
Safety IEC 62368-1:2014 and related national standards
UL 121201 / CSA C22.2 No. 213:2017 Class I, Div 2,
Groups C, D T4; Class II, Div 2 Groups F, G T4
Emissions RFI/EMC EN 55032:2015, Class A
EN 54098:2010
FCC CFR 47 subpart 15b, ICES 003:2017
AUS/NZ 4251.1
Immunity EN 55103-2:2009
Vibration/Shock BS EN 60721-3-2 Class 2M3
RoHS All parts of the system are compliant with EU directive 2011/65/EC